ibidi Heating System, Universal Fit, for 1 Chamber

£2,756.00£5,256.00

Key Features

Heating System for all live cell imaging applications including high resolution, TIRF, and confocal microscopy

  • Compatible with all microscopy platforms – fits every inverted microscope that has a frame or holder for 96 well plates
  • Excellent illumination of the sample – no condensation due to heated lid, optimal magnetic sample stabilization, and suitable for DIC
  • Perfectly suited for live cell imaging applications – full incubator conditions on the microscope
  • Available with or without Heated Lid

System includes:


ibidi Temperature Controller

Heated Plate for 1 Chamber in Multi-Well Format

Heated Glass Lid, Universal Fit

Heating Insert for ibidi
and non-ibidi Slide Formats
Clear
Special Requirements?

Description

Applications:

Rat fibroblasts (cell line)

Specifications:

Temperature Controller
Environmental humidity Relative humidity 0% – 99%
Environmental temperature +5°C – +40°C (50% rel. humidity)
Dimensions (H x W x D in mm) 90 x 170 x 230
Weight 3.4 kg
Input voltage 230 V / 50 Hz | 115 V / 60 Hz
Heated Plate and Lid
Dimensions Plate / Lid (in mm) 127.5 x 85.5 x 8 / 135 x 85.5 x 20.5
Height of the system 26.5mm
Weight of incubation chamber
with insert
330 g
Gas inlet Luer connector (M5 thread)
with Luer Lock
Restrictions for objective lenses None
Custom openings On request

Heating Stages for Live Cell Imaging – No Condensation

The independently controlled, heated glass lid of the ibidi Heating & Incubation System solves the problem of condensation in live cell imaging.

By heating the lid to a temperature higher than the plate, a vertical temperature gradient is created. This gradient and an active humidity control prevent the formation of condensation on the lid of the Petri dish. The temperature at the cells’ site is maintained at a constant 37 °C.

Components of the ibidi Heating & Incubation System, Universal Fit

ibidi Temperature Controller

  • Provides excellent temperature stability within the incubation chamber
  • Four control channels allow to connect a heated plate, a heated lid, and two additional heated components (e.g., an objective heater)

Technical Features:

  • Temperature stability: ± 0.05 °C
  • Temperature uniformity across the insert: ± 0.5 °C
  • Temperature range: Room temperature – 45 °C
  • Control channels: 4
  • TempControl software for remote control and data recording included
  • External temperature sensor included
  • Adjustable alarm function included
  • Analog output for extreme noise reduction optional

Heated Plate in a Multi-well Format for 1 Chamber

  • Can be used with any inverted microscopy system
  • Fits into both manual and automated stages
  • Can be placed into any regular multi-well frame that comes with your microscope
  • Adaptable to all types of microscopy chambers, such as µ-Slides and µ-Dishes plus non-ibidi formats

Heated Plate in a Multi-well Format for 4 µ-Slides

  • Can be used with any inverted microscopy system
  • Ideal for use with motorized stages
  • Can be placed into any regular multi-well frame that comes with your microscope
  • Compatibe with all ibidi µ-Slides and non-ibidi slide formats

Heated Glass Lid, Universal Fit, for Use with CO2 and Humidity

  • For use with CO2, O2, and humidity to provide a complete environmental chamber
  • Independently controlled glass lid, warmed to 40 °C, prevents the formation of condensed water on the lid of the microscopy chamber or plate
  • No scattering of light or shadow formation

Heating Inserts

Optional: Heating Insert Adapter for Perfusion Assays

Gas Mixer for the Incubation Unit

The heated lid also comes with a gas inlet. The ibidi Gas Incubation System upgrades the ibidi Heating System to a complete stage top incubator for all live cell imaging applications, including high resolution, TIRF, and confocal microscopy.

The ibidi Gas Incubation System is suitable for various experimental conditions (e.g., pH or hypoxia). It is available in two versions: Gas Mixer for CO2, Gas Mixer for CO2 and O2.

Live Cell Imaging Under Flow Conditions

The ibidi Heating & Incubation System can be adapted for live cell imaging under flow conditions. Connect the ibidi Pump System with the ibidi Heating System, Universal Fit, by using the Heating Insert Adapter for perfusion assays. This creates the perfect environment for long-term cell studies (several days) under flow conditions.

Overview of the Heating and Incubation System, Universal Fit

ibidi Heating System for Temperature Control of Multi-Well Plates

ibidi has developed a Heating System for the use with K-Frame Stages or the Nikon Ti-S-E and Ti-S-ER Motorized Stage which hold multi-well plates. Thus, this system permits the user to control the temperature of samples held in multi-well plates.

Special Solutions

You can also obtain additional customer-specific solutions upon request.

Additional information

With Heated Lid

Yes, No